VXI VT1538A DJ Equipment User Manual


 
Agilent E1538A Enhanced Frequency/Totalize/PWM SCP 73
Usage SOUR:RPULSE:POS:ANGL 20,(@145)
preset channel 45 pulse position
to 20 degrees
SOURce:RPULse:POSition[:ANGLe]?
SOURce:RPULse:POSition[:ANGLe]? (@<
channel
>) returns the angular
position set for <channel>,
Parameters
Comments <channel> must specify a single channel only
Usage SOUR:RPULSE:POS:ANGL? (@145)
return pulse pos set for channel
45
SOUR:RPULse:VARType
SOUR:RPULse:VARType <
type
>,(@<
ch_list
>) specifies the type of value
that will be controlled (varied) by the algorithm. Depending on how the
RPULse system is set up, the varied property can be either pulse position, or
pulse width.
Parameters
Comments <type> specifies the that the algorithm will send values of either:
ANGLe (in degrees) to the channel(s).
or
TIME (in seconds) to the channel(s).
<ch_list> specifies the SOUR:FUNC:RPUL channel(s) that will be
controlled (varied) by the algorithm. Channels in <ch_list> must be
referenced in a SOUR:FUNC:RPUL command before the next INIT
command. Related error messages:
3113, "Channel specified is not in same SCP as reference channel."
3114, "First channel in SCP can not be used in RPULse output channel
list."
Usage SOUR:RPULSE:VART ANGL,(@145:147)
algorithm will control pulse
width by ANGLE
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
channel string 100 - 163 none
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
type discrete (string) TIME | ANGLe seconds
ch_list string 100 - 163 none