Message Summary
Memory backup issues
Check Sum Error!
Check sum did not match between shutdown and startup.
A memory backup problem has occurred, perhaps because the battery is low.
Low Battery! The backup battery has run low. Replace the battery.
Low Battery !
Replace Battery !
The battery is low. Replace the battery.
Low Battery !
Factory Preset ? Replace Battery !
The battery is low. Replace the battery.
Battery is Exhausted !
Replace Battery !
The battery is dead. Replace the battery.
Communication issues
MIDI port is not selected!
This will appear if you attempt to execute a bulk dump with the MIDI PORT
unspecified.
Port busy. Try again.
Port Busy occurred while executing a MIDI bulk dump.
Try the operation once again.
TX buffer full. Try again.
TX Buffer Full occurred while executing a MIDI bulk dump.
Try the operation once again.
Work Memory full! Memory could not be allocated for the MIDI bulk dump.
MIDI Framing Error
There was a framing error in the message received at the MIDI port.
Check whether an appropriate device is connected.
MIDI Overrun Error
There was an overrun error in the message received at the MIDI port.
Check whether an appropriate device is connected.
MIDI Parity Error
There was a parity error in the message received at the MIDI port.
Check whether an appropriate device is connected.
MIDI RxBuf. Full
The MIDI port reception buffer has overflowed.
Cause: The amount of data being received is too great, or the system has been
loaded for an extended period of time.
MIDI TxBuf. Full
The MIDI port transmission buffer has overflowed.
Cause: The amount of data being transmitted is too great, or the system has
been loaded for an extended period of time.
SLOT1 Framing Error
There was a framing error in the message received at the SLOT1 serial port.
Check the serial bridge settings of the MY card.
SLOT1 Overrun Error
There was an overrun error in the message received at the SLOT1 serial port.
Check the serial bridge settings of the MY card.
SLOT1 Parity Error
There was a parity error in the message received at the SLOT1 serial port.
Check the serial bridge settings of the MY card.
SLOT1 RxBuf. Full
The SLOT1 serial port reception buffer has overflowed.
Cause: The amount of data being received was too great, or the system has been
loaded for an extended period of time.
SLOT1 TxBuf. Full
The SLOT1 serial port transmission buffer has overflowed.
Cause: The amount of data being transmitted was too great, or the system has
been loaded for an extended period of time.
USB RxBuf. Full
The USB port reception buffer has overflowed.
Cause: The amount of data being received was too great, or the system has been
loaded for an extended period of time.
USB TxBuf. Full
The USB port transmission buffer has overflowed.
Cause: The application on the communicating PC terminated abnormally, etc.
Disconnect and reconnect the cable, and restart the application.