52 Error messages
01V96i—Owner’s Manual
DIO issues
WRONG WORD CLOCK!
The wordclock is incorrect.
Cause: The device assigned as the clock source is not running, or a clock source
to which the 01V96i cannot synchronize has been selected.
Sync Error!(SLOT)
Synchronization has not been achieved with the input signal from the MY slot.
Check the clock source of the connected device.
Sync Error!(2TRD)
Synchronization has not been achieved with the 2TR Digital input signal.
Check the clock source of the connected device.
Sync Error!(ADAT IN)
Synchronization has not been achieved with the ADAT IN input signal.
Check the clock source of the connected device.
Memory store/recall issues
Y56K Couldn’t Store #xx : SLOT(1).
The Y56K/Y96K’s scene #xx could not be stored.
Cause: You selected scene 97 or later.
Y56K Couldn’t Recall #xx : SLOT(1).
The Y56K/Y96K’s scene #xx could not be recalled.
Cause: The scene had not been stored in the Y56K/Y96K, or you selected scene
97 or later.
Channel Library #xx Can’t Recall!
This message appears if you attempt to recall a channel library memory that was
created from a different channel module. For example, this will appear if a library
memory created for an Aux channel is recalled to an Input channel.
Nothing to Undo!
Undo is not possible because there is no data in the undo buffer.
This message will appear if you attempt to recall the undo buffer (#U) without
having executed Store or Recall since the console was powered-on.
Nothing to Paste.
The copy buffer is empty. This message will appear if you attempt to execute
Channel Paste before executing Channel Copy.
Can’t Paste to a Different Channel Type.
You cannot Paste because the channel module is different. For example, this mes-
sage will appear if you copy INPUT Channel 1 and attempt to paste it to AUX1.
For Effect 1,2 Only.
This effect type can be used only with EFFECT 1 and 2. This message will appear
if you attempt to recall HQ.PITCH or FREEZE to EFFECT 3 or 4.
AUX Pair Status Conflicted!
This message will appear if the saved CH Library memory and AUX have different
Pair settings. The library memory has been recalled, but the Pair settings for AUX
have not been reproduced.
Surround Mode Conflicted!
This message will appear if the channel library memory and the Surround Mode
settings are different. The library memory has been recalled, but the AUX pair
settings have not been reproduced.
Output Has No Gate!
This message will appear if you attempt to recall a Gate library memory to an
Output.
Stereo In Has No Gate!
This message will appear if you attempt to recall a Gate library memory to a Ste-
reo In.
Stereo In Has No Comp!
This message will appear if you attempt to recall a Comp library memory to a
Stereo In.
#xx of Scene is Read Only!
#xx of Channel Library is Read Only!
#xx of Gate Library is Read Only!
#xx of Comp Library is Read Only!
#xx of EQ Library is Read Only!
#xx of Effects Library is Read Only!
#xx of Input Patch Library is Read Only!
#xx of Output Patch Library is Read Only!
This message will appear if you attempt to execute an operation such as Store or
Title Edit on a read-only memory.
#xx of Scene is Protected!
This message will appear if you attempt to execute an operation such as Store or
Title Edit on a protected scene.
#xx of Scene is Empty!
#xx of Channel Library is Empty!
#xx of Gate Library is Empty!
#xx of Comp Library is Empty!
#xx of EQ Library is Empty!
#xx of Effects Library is Empty!
#xx of Input Patch Library is Empty!
#xx of Output Patch Library is Empty!
This message will appear if you attempt to recall a scene or library memory in
which no data has been saved