Korg Trinity Plus Musical Instrument User Manual


 
02: Limiter
16
c: Attack
d: Release
These parameters set the attack time and release time. A higher attack time will
cause the compression to be applied more slowly.
f: Side PEQ Insert
g: Side PEQ Cutoff [Hz]
g: Q
g: Gain [dB]
These parameters are used to set the EQ applied to the trigger signal.
The Limiter determines whether the compression is applied or not, based on the
sound post-EQ. Setting the equalizer allows you to set the Limiter to respond to
any frequency band.
h: Trigger Monitor
Setting this parameter On will cause the trigger signal to be output, instead of the
Limiter signal. Use this parameter to check the trigger signal with EQ applied.
Usually, set this to Off.
Input Level
Output Level
Threshold
Ratio=1.0 : 1
Ratio=2.0 : 1
Ratio=4.0 : 1
Ration=Inf : 1
Louder
Louder
Time
Level
Threshold
Ratio=Inf : 1
Ratio=2.0 : 1
Ratio=4.0 : 1
Dry
Ratio=1.0 : 1
Limiter - Threshold / Ratio
Threshold
Ratio=Inf : 1
Attack=1
Release=1
Ratio=Inf : 1
Attack=100
Release=100
Dry
Wet
Wet
Release
Attack
Limiter - Attack / Release