Korg Trinity Plus Musical Instrument User Manual


 
06: St. Parametric 4EQ
(Stereo Parametric 4-Band EQ)
55
size2
06: St. Parametric 4EQ
(Stereo Parametric 4-Band EQ)
This is a stereo 4-band parametric equalizer. You can select peaking type or shelving type for Band 1 and
4. The gain of Band 2 can be controlled by dynamic modulation.
aTrim 0100 Sets the input level.
b Band1 Type Peaking, Shelving-Low Selects the type for Band 1.
P.20
c Band4 Type Peaking, Shelving-High Selects the type for Band 4.
P.20
d
Band2 Dynamic Gain Src NoneTempo Modulation source of the Band 2 gain
P.21
Amt [dB] 18.0+18.0dB Modulation amount of Band 2 gain
e
Band1 Cutoff [Hz] 201.0kHz Sets the center frequency for Band 1.
Q 0.510.0 Band 1 bandwidth
P.19
Gain [dB] 18.0+18.0dB Sets the gain of Band 1.
f
Band2 Cutoff [Hz] 5010.00kHz Sets the center frequency for Band 2.
Q 0.510.0 Band 2 bandwidth
P.19
Gain [dB] 18.0+18.0dB Sets the gain of Band 2.
P.21
g
Band3 Cutoff [Hz] 30010.00kHz Sets the center frequency for Band 3.
Q 0.510.0 Band 3 bandwidth
P.19
Gain [dB] 18.0+18.0dB Sets the gain of Band 3.
h
Band4 Cutoff [Hz] 50020.00kHz Sets the center frequency for Band 4.
Q 0.510.0 Band 4 bandwidth
P.19
Gain [dB] 18.0+18.0dB Sets the gain of Band 4.
i Wet/Dry Dry, 1:9999:1, Wet Sets the balance between the effect and dry sounds.
Left
Right
Wet / Dry
Wet / Dry
Stereo In - Stereo Out
Band1
Band2
Band3
Band4
PEQ
PEQ PEQ PEQ
LEQ
LEQ
HEQ
HEQ
PEQ
PEQ PEQ PEQ
Trim
Trim
D
-mod