Roland SP-555 Music Mixer User Manual


 
24
Sampling (recording)
Here’s how to delete all samples from internal memory or the
CompactFlash card.
1.
Make sure that [PATTERN SELECT] is extinguished.
If it is lit, press [PATTERN SELECT] to turn it off.
2.
While holding down [CANCEL], press [DEL].
The display will indicate “dAL,” and [DEL] will light.
BANK [A]–[F/J] will blink.
If no CompactFlash card is inserted, BANK [C/G]–[F/J] will
not blink.
3.
Press one of the bank buttons to specify the memory
that you want to delete.
BANK [A] or [B]: Internal memory
BANK [C/G]–[F/J]: CompactFlash
* If you decide to cancel the operation at this point, press
[CANCEL].
4.
When you press [DEL], the samples will start being
deleted. When the deletion is complete, the “dAL”
indication in the display will disappear.
* Never turn off the power before the deletion is complete. Doing
so may destroy not only the samples being deleted, but also
other samples, or damage the CompactFlash card itself.
* Once you press [DEL] to begin deleting the samples, you won’t
be able to cancel the operation by pressing [CANCEL].
* If you specify a bank that is protected (p. 51), the display will
indicate “Prt” (Protected), and you won’t be able to delete
anything.
You can play back a sample with an effect applied, and then
newly sample the result. This is called “resampling.”
1.
Make sure that [PATTERN SELECT] is extinguished.
If it is lit, press [PATTERN SELECT] to turn it off.
2.
Apply an effect to the original sample, and adjust the
effect parameters.
3.
Press [RESAMPLE] so the button is lit. The display will
indicate “LEV.”
4.
Play back the original sample.
5.
Adjust the CTRL 3 (LEVEL) knob so that the display
illumination does not light red.
While [RESAMPLE] is lit, you can’t use the CTRL 3 knob to
adjust the effect depth. If you want to use the CTRL 3 knob to
adjust the effect depth, press [CANCEL] to make [RESAMPLE]
go out.
6.
Press [SAMPLING] so the button is blinking. The bank
buttons and pads to which resampling is possible will
start blinking.
7.
Press the pad to which you want to resample, so the
pad is lit.
You can also resample to a different bank.
You can’t resample to a pad to which a sample is already
assigned.
8.
Press [LO-FI] to select standard grade.
[LO-FI] unlit: STANDARD (high quality)
[LO-FI] lit: LO-FI (low fidelity)
If you’ve recorded a sample at LO-FI, resampling it at
STANDARD quality will not return it to its original quality.
9.
Press [STEREO] to choose stereo or monaural sampling.
[STEREO] lit: Stereo sampling
[STEREO] unlit: Monaural sampling
10.
Press [SAMPLING] so the button is lit. Resampling will
not yet begin at this point.
11.
Press the pad to which you want to resample. The
sample will begin playing, and resampling will start.
Never turn off the power during resampling. Turning off the
power at this time may destroy not only the sample being
resampled, but also other samples as well.
12.
When resampling is finished, press [SAMPLING].
13.
To hear the resampled sound, press the pad to which
you resampled.
Deleting all samples
Resampling
SP-555_e.book 24 ページ 2007年6月25日 月曜日 午前9時9分