A SERVICE OF

logo

Chapter 7. IBM iSeries 820, 830, and 840 features and placement 229
#0551
(cont.)
#0551 iSeries Rack
The IBM marketing configurator does not manage rack space in the #0551 iSeries Rack. Use the following list to determine
the number of EIA units required in the #0551 for each iSeries system unit or expansion tower:
Model 270 System Unit - 16 EIA units (includes 2 EIA for the #0133 and #0137)
#0595 PCI-X Expansion Unit in Rack - 5 EIA units
#0578 PCI Expansion Unit in Rack - 8 EIA units
#0588 PCI-X Expansion Unit in Rack - 8 EIA units
#5074 PCI Expansion Tower - 18 EIA units
#9079 Base I/O Tower - 18 EIA units
One to four PDUs can be ordered with the #0551. The PDUs can be on initial orders, model upgrades, or on MES orders.
Each PDU has six power sockets that can be used to provide power for devices rack mounted in the #0551 iSeries Rack
using the #1422 PDU Line Cord.
The following PDUs are available:
#5160 Power Distribution Unit 1 Phase NEMA
The following line cords are supported on the #5160 for connection to utility power:
#1424 - 200V 6-ft Locking Line Cord
#1425 - 200V 6-ft Watertight Line Cord
#1426 - 200V 14-ft Locking Line Cord
#1427 - 200V 14-ft Watertight Line Cord
#1446 - 4.3 m 200V/30A Power Cord Korea
#1447 - 4.3 m 200V/30A Power Cord AU
#1448 - 4.3 m 200V/30A Power Cord NZ
The #6654 14- foot1PH/24-30 Power cord is the recommended replacement for the #1426
The #6655 14- foot1PH/24-30 WR Power cord is the recommended replacement for the #1427
#5161 Power Distribution Unit - 1 Phase IEC
#1477 - 4.3 m 200V/ 16A IEC309/46 Power Cord
#1449 - 4.3 m 200V/ 32A Power Cord EU 1-Phase for connection to utility power.
#5162 Power Distribution Unit - 2 of 3 Phase
#1450 - 4.3 m 200V/ 16A Power Cord EU 2-Phase for connection to utility power.
#5163 Power Distribution Unit - 3 Phase
#1477 - 4.3 m 200V/ 16A IEC309/46 Power Cord
#7188 Power Distribution Unit 1 Phase NEMA
The following line cords are supported on the #7188 to connect to utility power:
#6489 - 14-ft 3PH/24A Power Cord
#6491 - 14-ft 1PH/63A Power Cord
#6492 - 14-ft 1PH/48-60A Power Cord
#6653 - 14-ft 3PH/16A Power Cord
#6654 - 14-ft 1PH/24-30A Power Cord
#6655 - 14-ft 1PH/24-30A Watertight Power Cord
#6656 - 14-ft 1PH/24A Power Cord
#6657 - 14-ft 3PH/24A Power Cord
#6658 - 14-ft 3PH/16A Power Cord Korea
Prerequisite: None
Supported on Models 820, 830, 840.
The #5160 Power Distribution Unit, #5161 Power Distribution Unit, and #5163 Power Distribution Unit were withdrawn from
marketing on 12 April 2005. The #7188 Power Distribution Unit is the recommended replacement.