Pattern Generation Modules Specifications
and Characteristics
Data Pod Characteristics
Note: Data Pod output parametrics depend on the output driver and the impedance load of the target
system. Check the device data book for the specific drivers listed for each pod.
Agilent 10461A TTL Data Pod
Output type 10H125 with 100 series
Maximum clock 200 MHz
Skew [1] typical < 2 ns; worst case = 4 ns
Recommended lead set Agilent 10474A
Agilent 10462A 3-State TTL/CMOS Data Pod
Output type 74ACT11244 with 100 series; 10H125 on non 3-state channel 7 [2]
3-state enable negative true, 100 Kto GND, enabled on no connect
Maximum clock 100 MHz
Skew [1] typical < 4 ns; worst case = 12 ns
Recommended lead set Agilent 10474A
Agilent 10464A ECL Data Pod (terminated)
Output type 10H115 with 330 pulldown, 47 series
Maximum clock 300 MHz
Skew [1] typical < 1 ns; worst case = 2 ns
Recommended lead set Agilent 10474A
ECL/TTL
100
10H125
100
74ACT11244
42
10H115
– 5.2 V
348