Agilent Technologies 16700 Musical Instrument Amplifier User Manual


 
98
State/Timing Modules Specifications and
Characteristics
Agilent Technologies 16760A
Supplemental Specifications and Characteristics (continued)
Synchronous state 1.5 Gb/s mode (only 1.25 Gb/s mode (only 800 Mb/s mode 400 Mb/s mode 200 Mb/s mode
analysis (continued) available with E5378A available with E5378A
and E5379A probes) and E5379A probes)
Maximum trigger 2 2 4 16 16
sequence levels
Maximum trigger 1.5 Gb/s 1.25 Gb/s 800 MHz 400 MHz 200 MHz
sequencer speed
Store qualification Default Default Default Default Default and per
sequence level
Maximum global counter N/A N/A N/A N/A 16,777,215
Maximum occurrence N/A N/A N/A N/A 16,777,215
counter
Maximum pattern/range 32 bits [3] 32 bits [3] 32 bits [3] 32 bits [3] 32 bits [3]
term width
Timer value range N/A N/A N/A N/A 100 ns to 4397 seconds
Timer resolution N/A N/A N/A N/A 4 ns
Timer accuracy N/A N/A N/A N/A ±(10 ns + 0.01% of value)
Timer reset latency N/A N/A N/A N/A 65 ns
Data in to BNC port out 150 ns 150 ns 150 ns 150 ns 150 ns
latency
Flag set/reset to evaluation N/A N/A N/A N/A 110 ns
latency
[1] In 1.25 Gb/s mode, only the even-numbered channels (0, 2, 4, etc.) are acquired.
[2] The resolution of the hardware used to assign time tags is 4 ns. Times of intermediate states are calculated.
[3] Maximum label width is 32 bits. Wider patterns can be created by Anding multiple labels together.
Asynchronous Timing Analysis Conventional Timing Analysis Transitional Timing Analysis
Maximum timing analysis sample rate 800 MHz 400 MHz
Number of channels 34 x (number of modules) Sampling rates < 400 MHz: 34 x (number of modules)
Sampling rates = 400 MHz:
34 x (number of modules) - 17 [1]
Maximum channels on a 170 (5 modules) 170 (5 modules)
single time base and trigger
Sample period 1.25 ns 2.5 ns to 1 ms [1]
Memory Depth 64 M Samples 32 M Samples [1]
[1] With all pods assigned in transitional/store qualified timing, minimum sample period is 5 ns and maximum memory depth is 16 M samples.