162 Chapter 8
io3000
io3000 error codes
Example of io3000 Symbios controller specific error message:
IOLF_B/ct1/f804000010/ffffff01/00000001
Table 59 shows each io3000 Symbios controller specific error code.
Table 59 io3000 Symbios controller specific errors
io3000 Tachyon controller specific errors
io3000 Tachyon controller specific error codes post the following error
message:
SAGA_name/ctlr_num/address/act_val/exp_val
Example of io3000 Tachyon controller specific error message:
IOLF_B/ct1/f804000010/ffffff01/00000001
Table 59 shows each io3000 Symbios controller specific error code.
Table 60 io3000 Symbios controller specific errors
Code Description
0x110 General failure detected on Symbios controller.
0x113 Error detected during SCRIPTS RAM pattern testing.
0x114 Interrupt test failed. The address is the address of the
interrupt register. The expected data contains the bit of that
interrupt register expected to be set, while the actual data
contains the entire contents of the ISTAT or DSTAT
register.
0x115 Symbios DMA test failed.
Code Description
0x90 PCI vendor ID not as expected.
0x91 PCI device ID not as expected.
0x93 PCI memory address Base Register write/read fail.