A SERVICE OF

logo

Chapter 3 61
Power-On Self Test
Interactive mode
Table 12 Name of scuba test enable for listed utilities
master_error_enable—Determines whether POST will enable
errors or not. This is used in conjunction with
use_error_overrides to determine how errors are enabled.
[default: true]
Table 13 Name of master error enable for listed utilities
use_error_overrides—Determines if POST will use the built-in
defaults for errors or the user error overrides. This is only checked if
master_error_enable is enabled. [default: false]
Table 14 Name of use error overides for listed utilities
force_monarch—Determines if POST will force the monarch
selection to a specific processor. The processor is specified in
monarch_number [default: false]
Utility Parameter name
OBP scubatest?
POST scuba_test_enable
sppdsh scuba_test_enable
Utility Parameter name
OBP master-error-enable?
POST master_error_enable
sppdsh master_error_enable
Utility Parameter name
OBP use-error-overrides?
POST use_error_overrides
sppdsh use_error_overrides