Aviom 6416M Music Mixer User Manual


 
108Fi rM wA re uPdAte
LEDs will flash to indicate that this function will interrupt normal network
operation. Press En t E r to enable the module to receive new firmware from
the PC host. Send the firmware update following the instructions that came
with the Pro64 Update Tool. During the update the sixteen red, yellow and
green channel meter LEDs will flash in sequence.
When the firmware update has been sent successfully, the module will
reset and normal front panel operation will be restored. If for some reason
the firmware update fails, refer to the error recovery information below for
instructions on how to recover and complete the update.
When a module is being updated locally, the dot in the VDC Slot display will
be on, indicating that a local firmware update is in progress.
When a module is waiting for a firmware update to begin, you can exit the
firmware update state by pressing the Ca n C E l button. If the firmware update
has not yet started, the module will attempt to reset, returning it to normal
operation.
P No t e : Do not press the Ca n CE l button while a firmware update is in
progress.
Error Recovery
In case of a partial firmware download or interruption to the firmware
transfer (as would happen because of a power failure, computer crash, or by
pressing the Cancel button in the middle of a firmware update), the module
can still be updated but will need to be powered up directly into the firmware
load mode. To do this, hold the VDC Slot decrement (down arrow) button
while powering up the unit. Then send the firmware from the computer as
described previously.
Firmware Update - via A-Net
To enable a Pro64 module to receive new firmware via A‑Net on an active
network, the PC must be connected to the RS‑232 port on the Control Master.
The network must be in Managed Mode to update firmware via A‑Net. All
network audio will be muted, and front‑panel functions will be disabled on
the module being updated.
To enable firmware updates, a module must be selected from within the
Pro64 Update Tool application, at which point it will be set up to receive
new firmware. Send the firmware update following the instructions that
came with the update firmware. During the update, the module’s sixteen
red, yellow, and green channel meter LEDs will flash in sequence. When the
firmware update has been sent successfully, the module will reset and audio
will be restored.