Aviom 6416M Music Mixer User Manual


 
436416M Front PAnel
Managed Button
The Managed button is used to put the network under control of a computer
for firmware updates, system monitoring, etc. Managed Mode can only be
engaged from the network’s Control Master.
When using a PC for firmware updates, etc., a Pro64 module cannot have
its RS‑232/422 or MIDI port assigned to a VDC when the PC is connected.
Deactivate these VDC assignments before entering Managed Mode.
Connecting a PC to the Control Master requires the use of the RS‑232 port for
communication. The RS‑232 baud rate DIP switches also need to be set to the
same rate as the computer application for data transfers.
To enter Managed Mode, press the Ma n a g E d button; its LED will flash. The
Enter/Cancel LED will also flash. Press En t E r to confirm the mode change or
Ca n CE l to return to the previous state.
To exit Managed Mode, press the Ma n a g E d button; its LED will flash and the
Enter/Cancel LED will flash. Press En t E r to confirm the mode change. The
network returns to the previous local mode, Auto or Manual.
In Managed Mode, Virtual Data Cable and channel Active buttons behave as
if the module is edit locked; they provide information only when pressed. All
other front panel edits are prohibited.
Edit Lock Button
The front panel of the 6416m can be locked to prevent accidental changes
or low‑level unauthorized access. Once edit locked, all front‑panel functions
under digital control cannot be changed. Edit Lock can be used on a module‑
by‑module basis.
To lock a module’s front panel, press the Ed i t lo C k button. The Enter/Cancel
LED will blink. Press En t E r to lock the unit. No other Pro64 modules in the
network are affected. Press the Ca n C E l button to exit the operation without
locking the device’s front panel.
To unlock a Pro64 device, press the Ed i t lo C k button again. The Enter/Cancel
LED will blink. Press the En t E r button to unlock the unit. Press Ca n C E l to exit,
leaving the unit locked.
When a Pro64 module is edit locked, all front panel operations are inactive
with the following exceptions:
The Edit Lock button, along with the Enter button,• can be
used to unlock the unit.
•Gain switches on I/O modules such as the 6416i are analog
controls. These cannot be locked.
Channel • Active buttons can be used to get information