Aviom 6416M Music Mixer User Manual


 
556416M Front PAnel
P No t e : To save a mic preamp Preset from the MCS, remember that the
6416m needs to be set to the same Control Group as is currently
selected on the RCI that the MCS is connected to.
Recall a Preset
To recall a mic preamp Preset from the front panel of the 6416m, press the
rE C al l button. The Recall button’s red LED, the Enter/Cancel LED, and the
Edit button corresponding to the last Preset saved/recalled will flash. Choose
the memory location that contains the desired Preset by pressing the
corresponding channel Active button. Press En t E r to complete the operation
and load the Preset, or press the Ca n C E l button to exit without recalling a
Preset.
Recalling a preset will overwrite all channel parameters as described above;
save a mic preamp Preset first if you want to recall the current settings at a
later time. When a Preset is recalled, audio is muted briefly (a few milliseconds)
while the settings are changed. This is desirable, especially when large gain
changes or changes to pad and phantom power settings are included in a
Preset.
Remember that when using the MCS Mic Control Surface to recall a mic
preamp Preset, the 6416m needs to be set to the same Control Group as
the RCI/MCS combination. Using the MCS to recall a Preset causes all 6416m
preamps in the same Control Group to recall the same‑numbered Preset
simultaneously.
Preset Rules
When saving or recalling a mic preamp Preset from the front panel of
an individual 6416m Mic Input Module, only that module is affected. For
example, to save the channel strip settings for a 64‑input system that includes
four 6416m mic modules in a network without an RCI/MCS combination, you
need to perform the save/recall operation on each module separately.
The Control Group has no bearing on the preset save/recall function when a
preset is saved or recalled from the 6416m front panel.
When an RCI Remote Control Interface and MCS Mic Control Surface are part
of a Pro64 network, the setting of the Control Group will affect the behavior
of the save/recall functions. Only modules set to the same Control Group can
be addressed from the RCI/MCS combination.
When a Preset is saved (or recalled) from the RCI/MCS combination, all
6416m modules set to the same Control Group will save or recall the same
numbered Preset simultaneously.