59
If you have edited a mix and have not stored it to a memory location,
this mix will not be recalled when the SysEx data is loaded into the
A-16R later.
Loading . via MIDI
The A-16R can load Presets saved as either single Preset files or as All
Preset files that include the complete set of sixteen memory locations.
As when recalling a Preset from the internal memory, you must first
enter Recall Mode to load a Preset. (Recall Mode on the A-16R is
entered by pressing the R
ECALL button.)
Remember that you need to have MIDI cables properly connected
between the A-16R and your MIDI recording devices to load presets.
Connect MIDI Out from your storage device to MIDI In on the A-16R.
Loading One Preset via MIDI
To load a single Preset that was saved to a MIDI recording device, the
A-16R must first be placed into Recall Mode. Remember that MIDI
reception is activated only when the front panel REMOTE/LOCAL switch
is in the L
OCAL position.
While waiting for valid MIDI SysEx information, the A-16R will
remain in MIDI Recall until a valid A-16R MIDI message is received,
or until you press another front panel button to exit MIDI mode. SysEx
information for other manufacturer’s devices will pass through the
A-16R and be ignored.
To load one Preset:
1. Set the A-16R R
EMOTE/LOCAL switch to the LOCAL posi-
tion.
2. Press the R
ECALL button. The RECALL button LED
flashes.
3. Press the S
OLO button to arm the A-16R for MIDI
reception. The LED in the SOLO button will blink.
4. Send the single Preset SysEx data from your MIDI
storage device.
5. The Preset is loaded into internal memory and is ready
to be used as is and/or edited.
6. Save your Preset to an internal memory location.
When a SysEx transfer is complete, the system will display a status
message to confirm that the data was received properly. Two messages
are possible:
• Valid Data Received - all yellow Mute LEDs will flash
• Invalid Data or MIDI Error - all red Channel LEDs will