Sample Edit
Sample Parameters
Here you can make various settings for the sample.
1.
In the Sample Edit screen, press [F2 (Sample
Param)].
2.
Use [CURSOR (up/down)] to select a parameter.
3.
Use [VALUE] or [INC/DEC] to edit the value.
4.
Press [F6 (Close)] when you are finished.
About the Loop Mode
FWD (Forward)
After the Sample played back from the Start point to the End point, it
will then be repeatedly played back in the forward direction, from
the Loop Start point to the End point.
ONE-SHOT
The sample will be played back only once, from the Start
point to the End point.
REV (Reverse)
When the sample has been played back from the End point to the
Start point, it will be repeatedly played back in the reverse direction,
from the Loop Start point to the Start point.
REV-ONE (Reverse One-shot)
The sample will be played back only once from the End point to the
Start point in the reverse direction.
Parameter
Values Explanation
Loop Mode
FWD,
ONE-SHOT,
REV,
REV-ONE
How the sample will be played
Refer to “About the Loop
Mode” (p. 116)
Loop Tune -50– +50 Pitch of the loop region
Make fine adjustments in
one-cent (1/100 semitone) in-
crements.
Original Key 24 (C1)–
127 (G9)
Note number that will play the
sample at the pitch at which it
was sampled
BPM 5–300 Original BPM of the sample
* You will need to edit this val-
ue when using Auto Sync.
Time Stretch
Type
TYPE01–
TYPE10
Auto sync method
Decreasing this value will op-
timize the sound for more
rapid phrases, and increasing
this value will optimize the
sound for slower phrases.
Start Fine 0–255 Fine adjustment of the Start
point.
Loop Start
Fine
0–255 Fine adjustment of the Loop
Start point.
Loop End
Fine
0–255 Fine adjustment of the End
point.
Start
Loop
Start P. End P.
Start
Loop
Start P. End P.
Start
Loop
Start P. End P.
Start
Loop
Start P. End P.
MC-909_Ref_e.book 116 ページ 2005年3月1日 火曜日 午後3時29分