Roland MC-909 Musical Instrument User Manual


 
129
System
Menu
Sound
Here you can specify the tuning and how the sound is to be produced.
Sampling
Here you can make sampling-related settings.
Device ID 17–32 Device ID number of a systemexclusive message on the MC-909
A system exclusive message can only be received if the device number included in the message matches
the device ID number set up on the receiving MIDI equipment. Using this function enables different Sys-
tem Exclusive messages to be received by more than one MC-909 unit at the same time.
* At the factory settings, the device ID number is set to “17.”
Receive Program
Change
OFF, ON Specifies whether or not each part will receive program changes. When this is “OFF,” program changes will
not be received.
Receive Bank Se-
lect
OFF, ON Specifies whether or not each part will receive bank select messages. When this is “OFF,” bank select mes-
sages will not be received.
Receive Exclu-
sive
OFF, ON Specifies whether or not each part will receive system exclusive messages. When this setting is “OFF,” sys-
tem exclusive messages will not be received.
Parameter Range Explanation
[F1 (Sound/Tune)]
Master Tune 415.3–466.2 Hz Adjusts the overall tuning of the MC-909.
The setting expressed as the frequency played by the A4.
Master Level 0–127 Adjusts the volume of the entire MC-909.
Output Gain -12– +12 dB Adjusts the output gain from the MC-909’s Analog Out and Digital Out.
Metronome Level 0–10 Adjusts the volume of the metronome.
Master Key Shift -24– +24 Shifts the overall pitch of the MC-909.
Patch Remain OFF, ON Specifies whether currently sounding notes will continue sounding when another patch or
rhythm set is selected (ON), or not (OFF).
[F2 (Sound Control)]
Rhythm Octave
Switch
OFF, ON Specifies the [OCT +/-] buttons will have effect when a rhythm set is assigned to current part
(ON), or not (OFF).
Resonance Limiter 50–127 Specifies the range in which the [RESONANCE] knob can be adjusted.
As this setting is increased, the variable range of the [RESNANCE] knob will increase.
LFO Morphing
Switch
OFF, ON Specifies whether LFO1 Waveform will be modified smoothly by the knob (ON) or not (OFF).
Parameter Range Explanation
[F1 (Sampling)]
Default File Type
WAV, AIFF File format used when saving a sample
Preset Default Load OFF, ON Specifies whether the preset samples will be loaded into memory at power-on (ON) or not
(OFF).
Sample Default Load OFF, ON Specifies whether the samples of the user area and memory card will be loaded into mem-
ory at power-on (ON) or not (OFF).
Pre Sample Time 0–1000 ms The length of sound preceding the moment at which sampling was manually or automati-
cally initiated that will be captured in the sample
This lets you prevent the attack portion of the sound from being omitted from the sample.
Trigger Level 0–7 Volume level at which sampling will begin when Auto Trig is ON
A setting of 0 is the minimum.
Gap Time 500, 1000, 1500, 2000 ms Length of silence at which the sample will be divided
Whenever there is a silent region longer than the specified time, the sample will be divid-
ed at that point, and the next sample number will be assigned to the sound that follows.
* This parameter is valid only when you are using Auto Divide Sampling.
External Source Select LINE-L-R, LINE-L,
DIGI-OPT,
DIGI-COAX, MIC
Input source of the external input sound
LINE-L-R:
INPUT jacks L/R (stereo)
LINE-L:
INPUT jack L (mono)
DIGI-OPT:
Digital Input (Optical)
DIGI-COAX:
Digital Input (Coaxial)
MIC:
INPUT jack (mono, mic level)
Trimming Switch OFF, ON If this is turned on, the Start point and End point settings will be automatically adjusted af-
ter sampling is performed, so any silent portions at the beginning or end of the sampled
sound are excluded.
Parameter
Range Explanation
MC-909_Ref_e.book 129 ページ 2005年3月1日 火曜日 午後3時29分