38
Enhancements related to operation
Shift Lock on/off
([SHIFT]+[YES])
It is now possible to control the Shift Lock switch (which
temporarily keeps [SHIFT] activated while it is not actually
pressed) without opening the System Parameter window
(VS-1680 Owner’s Manual, p. 187).
1. Press [PLAY (DISPLAY)].
2. Hold down [SHIFT] and press [YES].
fig.6-30
3. Thereafter, each time you hold down [SHIFT] and press
[YES], Shift Lock can be toggled on/off.
MEMO
When Shift Lock is OFF, the SHIFT indicator will light only
while you continue pressing [SHIFT]. When Shift Lock is
ON, the SHIFT indicator will light, or go out each time you
press [SHIFT]. [SHIFT] is active when the SHIFT indicator is
lit.
Removing direct current
offset from the mix bus
Direct current offset on the mix bus can be removed.
For example, in some cases the level meters of a device
(mixer etc.) connected to the output of the VS-1680 may
move even though no sound is being output. This is caused
by a direct current offset on the mix bus (MASTER output,
etc.). This component can be removed.
1. Press [PLAY (DISPLAY)].
2. Hold down [SHIFT] and press [F5 (SYSTEM)].
3. Make sure that the System menu is displayed. If not,
press [F6 (EXIT)].
4. Press [PAGE] so that [F2] indicates “GLOBL,” and then
press [F2 (GLOBL)].
5. Use [ ][ ][ ][ ] to move the cursor to
“DC Cut,” and use the TIME/VALUE dial to make the
setting.
If “DC Cut” is not shown, press [F2 (Prm2)], and use the
TIME/VALUE dial to make the setting.
fig.6-31_75
DC Cut
When this is turned “On,” any direct current offset on the
mix bus will be removed before output.
6. Press [PLAY (DISPLAY)].