Sanyo Digital Video Recorder Recording Equipment User Manual


 
ALARM REC MODE SET SETTING
Pre-alarm recording setting
1
Use the jog dial to move the cursor to the ALARM
RECORDING setting, and then turn the shuttle dial clockwise.
OFF flashes.
2
Use the jog dial to change the OFF setting to some other
mode (example: MODE1), and then turn the shuttle dial
clockwise.
The PRE-ALARM RECORDING setting changes from “*** to
OFF”.
The cursor moves to REC CYCLE.
3
Use the jog dial to move the cursor to the PRE-ALARM
RECORDING setting, and then turn the shuttle dial clockwise.
OFF flashes.
4
Use the jog dial to change from “ OFF” to “ ON” , and then turn
the shuttle dial clockwise.
The cursor moves to REC CYCLE.
5
Turn the shuttle dial clockwise, use the jog dial to set the
recording speed (example: “ A0.20), and then turn the
shuttle dial clockwise.
The cursor moves to the 1SEC setting for DURATION and
flashes.
6
Use the jog dial to set the recording time duration (example:
5SEC” ), and then turn the shuttle dial clockwise.
The cursor moves to ALARM TRIGGER.
7
Press the EXIT/OSD button.
The display returns to the normal screen.
PRE appears in the operating display section. When an alarm is
triggered, the display switches to ALARM”.
Note:
Pre-alarm recording continues for the length of time specified by
the DURATION setting before an alarm signal is input. When
playing back images that have been recorded during pre-alarm
recording, use the alarm search (SEARCH FRAME/FIELD button)
operations. Images will be played back from the point that the
alarm occurred, so use the shuttle operations to carry out rewind
playback.
If pre-alarm recording is being carried out in FIELD (recording rate)
mode, the cycle speed for the recording cycle settings will become
slower, and the 0.02 second and 0.03 second settings cannot be
selected.
If carrying out normal alarm recording and pre-alarm recording at
the same time, no audio signals will be recorded with the pre-alarm
recording images.
If using the digital video recorder together with a multiplexer, the
switching signal from the multiplexer will be output in accordance
with the digital video recorders recording timing for normal
recording if pre-alarm recording and normal recording are being
carried out at the same time. Because of this, if the recording cycle
for pre-alarm recording is shorter than the recording cycle setting
for normal recording, pre-alarm recording images from one camera
may be continuously recorded. On the other hand, if the recording
cycle for pre-alarm recording is longer than the recording cycle
setting for normal recording, camera images may not be recorded
at all during normal recording, so this setting should not be made.
<ALARM REC MODE SET>
PICTURE QUALITY : SUPER FINE
FRAME/FIELD RECORDING : FRAME
AUDIO RECORDING : ON
ALARM RECORDING : OFF
REC CYCLE : A0.13SEC. DURATION: 5SEC
PRE-ALARM RECORDING : ¤¤¤
REC CYCLE : ¤¤¤ SEC. DURATION: ¤¤¤
<ALARM REC MODE SET>
PICTURE QUALITY : SUPER FINE
FRAME/FIELD RECORDING : FRAME
AUDIO RECORDING : ON
ALARM RECORDING : MODE1
REC CYCLE : A0.13SEC. DURATION: 5SEC
PRE-ALARM RECORDING : OFF
REC CYCLE :
¤¤¤
SEC. DURATION:
¤¤¤
=> (03355 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
ALARM RECORDING : MODE1
REC CYCLE :A0.13SEC. DURATION: 5SEC
PRE-ALARM RECORDING : OFF
REC CYCLE :
¤¤¤
SEC. DURATION:
¤¤¤
=> (03355 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
PRE-ALARM RECORDING : ON
REC CYCLE : A0.20SEC. DURATION: 1SEC
=> (02960 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
PRE-ALARM RECORDING : ON
REC CYCLE : A0.20SEC. DURATION: 1SEC
=> (02844 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
REC CYCLE : A0.13SEC. DURATION: 5SEC
PRE-ALARM RECORDING : ON
REC CYCLE : A0.20SEC. DURATION: 5SEC
=> (02844 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
EXIT/OSD
01-01-01 PRE 0000
06:46:15 SF 0.26SEC
Recording
Rate
(field/sec)
Recording
Cycle (SEC)
PICT
BASIC NORMAL E
15 kB 22 kB
60.00 0.02 21H 15H
30.00 0.03 42H 30H
20.00 0.05 63H 45H
15.00 0.07 85H 60H
10.00 0.10 127H 90H
7.50 0.13 170H 120H
6.00 0.17 212H 150H
56