Yamaha D24 Musical Instrument User Manual


 
124 Chapter 11Wordclocks
D24—Owner’s Manual
Selecting a Wordclock Source
The wordclock source is selected using the Wordclock function. The source setting also
determines the sampling rate, which is set when a new project is created. Once some-
thing has been recorded in a project, the sampling rate cannot be changed, so it’s
important that you set the correct rate when creating a new project. See “About
Projects” on page 30 for more information.
1 Press the [SETUP] button.
The SETUP indicator lights up.
2 Use the JOG/DATA dial to select WORD CLOCK, and then press the [ENTER]
button.
The currently selected wordclock source appears on the display.
3 Use the JOG/DATA dial to select a wordclock source.
The following wordclock sources can be selected:
For all non-DUAL sources, the sampling rate is the same as the wordclock frequency.
4 Press the [ENTER] button to activate your selection, or the [CANCEL] button
to cancel the Word Clock function.
The D24 checks the selected source to see if an acceptable wordclock signal
is available. If such a signal exists, the D24 locks to it and the LOCK indi-
cator appears on the display, as shown here.
When an internal wordclock is selected, “INT” appears in the WC win-
dow on the display, and when an external source is selected, “EXT”
appears, as shown here.
The sampling rate appears in the FS window, as shown here.
Source Description
INT 44.1K
Internal 44.1 kHz wordclock
INT 48K
Internal 48 kHz wordclock (default setting).
WC IN
External wordclock via the BNC WORDCLOCK INPUT
(41.454 kHz50.88 kHz).
SLOT 1
External wordclock via SLOT 1 (41.454 kHz50.88 kHz).
SLOT 2
External wordclock via SLOT 2 (41.454 kHz50.88 kHz).
COAXIAL IN
External wordclock via the COAXIAL STEREO DIGITAL INPUT
(41.454 kHz50.88 kHz).
INT88.2KDUAL
Internal 44.1 kHz wordclock, 88.2 kHz sampling rate, and Dual
AES/EBU mode.
INT96K DUAL
Internal 48 kHz wordclock, 96 kHz sampling rate, and Dual AES/EBU
mode.
WC IN DUAL
External wordclock via the BNC WORDCLOCK INPUT
(41.454 kHz50.88 kHz) and Dual AES/EBU mode. The sampling rate is
double the wordclock frequency.
SLOT 1 DUAL
External wordclock via SLOT 1 (41.454 kHz50.88 kHz) and Dual
AES/EBU mode. The sampling rate is double the wordclock frequency.
SLOT 2 DUAL
External wordclock via SLOT 2 (41.454 kHz50.88 kHz) and Dual
AES/EBU mode. The sampling rate is double the wordclock frequency.
LOCK
WC
WC INT
EXT
44.1K
48K
96K
FS
FS
FS