A SERVICE OF

logo

Danaher Motion 07/06 Objects
M-S2-021-11 Initial Release 67
6. 36 SDO 6060H: MODES OF OPERATION (DS402)
This object is used to set the mode, which can be read out by SDO 6061h. Two types of operating mode can
be distinguished:
Manufacturer-Specific Operating Modes
These modes of operation have been optimized to the functionality of the equipment.
Operating Modes As Per Canopen Drive Profile DS402
These operating modes are defined in the CANopen drive profile DS402.
After the mode has been changed, the corresponding setpoint must be set once more (for instance, the
homing velocity in the mode homing_setpoint). If the position or jogging mode is stored, then the Homing
mode is set after a RESET of the servo amplifier.
WARNING
Never change the mode while the motor is running! The drive could do unexpected
movements.
When the amplifier is enabled, a mode change is only permissible at zero speed. Set the
speed setpoint to 0 before changing over.
CAUTION
An operating mode only becomes valid when it can be read by SDO 6061
h
.
Index
6060h
Name
mode of operation
Object code
VAR
Data type
INTEGER8
Category
mandatory
Access
rw
PDO mapping
possible
Value range
80h ... 88h, 1, 3, 4, 6, 7
Default value
Supported modes (negative values are manufacturer specific modes):
Value (hex) Mode
80 Digital velocity control mode
81 Analogue velocity control mode
82 Digital current control mode
83 Analog current control mode
84 Electronic gearing
85 reservedt
86 reserved
87 reserved
88 Motion task mode
1 Profile position mode
3 Profile velocity mode
4 Profile torque mode
6 Homing mode
7 Interpolated position mode