Roland MC-09 Electronic Keyboard User Manual


 
73
Error messages
If you perform an incorrect operation or if the data could not be processed as you specified, an error
message will be displayed. Refer to the explanation for the error message that appears, and take
the appropriate action.
Message Cause Action
E01
A large number of MIDI messages were received all at
once, and processing could not be completed.
Reduce the amount of data that is being transmitted.
E02
There is a problem with the MIDI cable connection. Check whether the MIDI cable is broken or disconnect-
ed.
E03
The checksum value of a received exclusive message is
incorrect.
Correct the checksum value.
E04
The format of a received exclusive message is incorrect. Check the data that is being transmitted, and perform
the operation once again. Also check whether a MIDI
cable is disconnected or broken.
E05
It is possible that the contents of internal memory have
been damaged.
Try performing the Factory Reset operation. If this does
not resolve the problem, contact a Roland service cen-
ter.
E12
The specified file does not exist on the memory card. Specify the file number of an existing file.
E13
The file has an incorrect data format, or has been dam-
aged.
Specify a file of the correct data format.
E14
There is insufficient space on the memory card. Delete unneeded files to create free space on the mem-
ory card.
E15
The memory card is write-protected. Remove the write protect label.
E16
The memory card is not inserted. Insert the memory card correctly.
E17
The memory card is not formatted. Format the card on the MC-09.
The MC-09 does not support this memory card. Use a memory card that the MC-09 supports.
The memory card is damaged. Replace it with a correctly-functioning memory card.