Roland XV-5080. Musical Instrument User Manual


 
110
Chapter 3 Selecting Output Jacks
Example of Settings
Assigning Different Output
Destinations for the Tones in a Patch
In this example, lets suppose we have a Patch composed of
four Tones, and we are outputting Tone 1 from the A
OUTPUT jacks, Tone 2 from the B OUTPUT jacks, Tone 3
from the INDIVIDUAL 5 jack, and Tone 4 from the
INDIVIDUAL 6 jack. The Chorus and Reverb are output
from the B OUTPUT jacks.
First, set the output destination for each Tone.
1. Select the Patch you wish to set.
2. Press [F6 (Effects)].
3. Press [F1 (General)] to call up the PATCH Effects General
page.
4. Use TONE SELECT [1][4] to select the Tone you wish to
set up.
5. Press [ ]/[ ]/[ ]/[ ] to move the cursor to
the parameter you wish to set, and rotate the VALUE
dial, or press [INC] or [DEC] to set the value as follows.
Tone Output Tone Dry Tone Chorus Tone Reverb
Assign Send Level Send Level Send Level
Tone 1 A 127 100 100
Tone 2 B 127 100 100
Tone 3 5 127 100 100
Tone 4 6 127 100 100
The Chorus and Reverb send levels can be set to any value
you wish other than 0.
6. Press [EXIT] to return to the PATCH PLAY page.
7. Press [F1 (Common)].
8. Press [ ]/[ ] to move the cursor to Output Assign.
9. Turn the VALUE dial or press [INC]/[DEC] to select
TONE.
10. Press [EXIT] to return to the PATCH PLAY page.
Next, select the Chorus output destination and set its overall
level.
11. Press [F6 (Effects)].
12. Press [ ]/[ ]/[ ]/[ ] to move the cursor to
Chorus Output Assign.
13. Turn the VALUE dial or press [INC]/[DEC] to select B.
14. Press [ ]/[ ]/[ ]/[ ] to move the cursor to
Chorus Level.
15. Turn the VALUE dial to select 100.
16. Press [ ]/[ ] to move the cursor to Chorus Output
Select.
17. Turn the VALUE dial or press [INC]/[DEC] to select
MAIN.
Finally, select the Reverb output destination and set its
overall level.
18. Press [ ]/[ ]/[ ]/[ ] to move the cursor to
Reverb Output Assign.
19. Turn the VALUE dial or press [INC]/[DEC] to select B.
20. Press [ ]/[ ]/[ ]/[ ] to move the cursor to
Reverb Level.
21. Turn the VALUE dial to select 100.
22. Press [EXIT] to return to the PATCH PLAY page.