Roland XV-5080. Musical Instrument User Manual


 
192
Chapter 7 Loading a Variety of Data
fig.07-04.e_70
f
5. Turn the VALUE dial or press [ ] or [ ] to select the
Sample to be transmitted, then press [F5 (Mark)]. Press
[F4 (Mk All) if you want to set markers in all samples.
Press this once more to remove all markers.
* This displays the number and size of marked samples on the
display.
6. Press [F6 (Trans)] to initiate the transmission.
The following message appears on the display:
Transmitting....
* Reception using Sample Dump Standard can only be done in
this mode.
Receiving Samples
1. Connect the XV-5080 and the transmitting sampler with
a MIDI cable.
For instructions on making the transmitting sampler settings,
refer to the owners manual for the connected device.
2. Press [SYSTEM/UTILITY], getting its indicator to start
blinking.
* If the indicator is steadily lit, you are in SYSTEM mode. Press
[SYSTEM/UTILITY] once again, so the indicator is blinking.
3. Press [F6 (Menu)] to select Menu 2.
4. Press the [F2 (S-Dump)] button.
The Sample Dump Standard page appears.
This completes the preparations needed for reception.
5. Transmit the Sample from the transmitting device.
The following message appears in the display: Receiving....
Free Area
SIMM
This displays the amount of free space in the SIMM.
Marked
The number and size of marked files to be processed are
displayed.
Emphasizing and Suppressing
the High End of Loaded Samples
(Emphasis)
Emphasizing the high range frequencies in data received in a
Sample Dump from another manufacturers sampler may
improve the sound quality of the samples. Furthermore,
when samples (wave data) are transmitted to another
manufacturers sampler, the high end of the samples may be
boosted in the destination device. In such instances, by
suppressing the high frequencies prior to transmission, you
can minimize the changes in sound quality that could occur
as a result of the transmission.
1. Press [SYSTEM/UTILITY], getting its indicator to start
blinking.
* If the indicator is steadily lit, you are in SYSTEM mode. Press
[SYSTEM/UTILITY] once again, so the indicator is blinking.
2. Press [F6 (Menu)] to select Menu 2.
3. Press [F4 (Emphasis)].
The Emphasis page will appear.
ig.07-05.e_70
f
4. Turn the VALUE dial or press [ ] or [ ] to select the
sample whose high end is to be emphasized or
suppressed, then press [F4 (Mark)]. Press [F3 (Mk All) if
you want to set markers in all samples. Press this once
more to remove all markers.
5. If emphasizing the high end, press [F6 (+Emphas)]. If
suppressing the high end, press [F5 (-Emphas)].
Free Area
SIMM
This displays the amount of free space in the SIMM.
Marked
The number and size of marked files to be processed are
displayed.
Processing
This indicates the approximate time required for processing
Emphasis.