The XV-5080 has two MIDI IN connectors. By providing for
the use of two MIDI IN connectors, the XV-5080 readily
accommodates a broad variety of performance situations.
The XV-5080s MIDI IN 1 connector is usually used for
keyboard performances and the like, whereas the MIDI IN 2
connector is designed as an auxiliary connector, convenient
for using a connected sequencer or other device playing
accompaniment.
* If using only one of the MIDI IN connectors, we recommend
that you use MIDI IN 1.
In Patch/Rhythm Set Mode
Both MIDI IN 1 and 2 will be received.
fig.09-MIDI IN-1.e
In Performance Mode
The MIDI messages from MIDI IN 1 and 2 are received, for
32 Parts.
Furthermore, you can set the MIDI IN 1/2 reception switch
for each of the Parts (p. 165). This means, for example, that
you can play Parts 116 with the messages from MIDI IN 1
and Parts 1732 using the messages from MIDI IN 2.
fig.09-MIDI IN-2.e
When Using the XV-5080 as a GM Sound
Module
When switching to GM mode by pressing the GM button
on the panel:
The MIDI messages from both MIDI IN 1 and 2 are received
as 16 GM2 parts.
fig.09-MIDI IN-3.e
Reception of GM ON or GS Reset at MIDI IN
The status of the XV-5080 changes as follows, depending on
the connector through which a GM ON or GS Reset has been
received.
When GM ON or GS Reset is received at MIDI
IN 1:
Instates the same status as that which would be entered if the
GM button on the panel were pressed to switch to GM mode.
fig.09-MIDI IN-4.e
* When GM ON or GS Reset is received at MIDI IN 2:
In Patch/Rhythm Set Mode
The instrument plays XV-5080 Patches while functioning as a
16-part GM2 sound module.
You cannot use the panel to select GM2 sound module tones
from MIDI IN 2, nor can you edit these tones. They can only
be controlled with an external MIDI device.
IN 1
Patch
IN 2
IN 1
Performance
IN 2
Part IN2
RX Switch
Part IN1
RX Switch
IN 1 IN 2
GM2 16Part
IN 1 IN 2
GM2 16Part