Roland XV-5080. Musical Instrument User Manual


 
113
Chapter 3 Selecting Output Jacks
Chap.3
SYSTEM General #1 page ([SYSTEM] -
[F1 (General)])
Master
Level (Master Level)
Range: 0127
Adjusts the volume of the entire XV-5080.
Example of Settings
Selecting Different Output Destinations
for Parts in a Performance
This example describes the procedure for outputting Part 1
from the A (MIX) OUTPUT jacks without sending it through
any internal effects, sending Part 2 through the Multi-effects
A and then outputting it from the B OUTPUT jack, and
outputting Part 3 from the INDIVIDUAL 5 OUTPUT jack
without sending it through any internal effects.
First, set Part 1.
1. Select the Performance you wish to use.
2. Press [F6 (Effects)].
3. Press [F1 (General)] several times to call up the
Performance Effects General #1 page.
4. Press PART SELECT [1/17] to make its indicator light.
* Make sure that the [1-16/17-32] button’s indicator is not lit. If
the indicator is lit, press [1-16/17-32] to turn it off.
5. Press [ ]/[ ]/[ ]/[ ] to move the cursor to
Part Output Assign.
6. Turn the VALUE dial or press [INC]/[DEC] to select
A.
7. Press [ ]/[ ]/[ ]/[ ] to move the cursor to
Part Dry Send Level.
8. Turn the VALUE dial to select 100.
9. Press [ ]/[ ]/[ ]/[ ] to move the cursor to
Part Chorus Send Level.
10. Turn the VALUE dial to select 0.
11. Set the Part Reverb Send Level setting to 0 in the same
way.
Next, set up Part 2.
12. Press PART SELECT [2/18], getting its indicator to light.
* Make sure that the [1-16/17-32] button’s indicator is not lit. If
the indicator is lit, press [1-16/17-32] to turn it off.
13. Press [ ]/[ ]/[ ]/[ ] to move the cursor to
the parameter you wish to set, and rotate the VALUE
dial, or press [INC] or [DEC] to set the value as follows.
Part Output Part Dry Part Chorus Part Reverb
Assign Send Level Send Level Send Level
MFX-A 100 0 0
The Part Dry Send Level can be set to any value you wish
other than 0.
14. Press [ ]/[ ]/[ ]/[ ] to move the cursor to
the parameter you wish to set, and rotate the VALUE
dial, or press [INC] or [DEC] to set the value as follows.
MFX MFX Dry MFX Chorus MFX Reverb
Output Assign Level Send Level Send Level
B 100 0 0
Finally, set up Part 3.
15. Press PART SELECT [3/19], getting its indicator to light.
* Make sure that the [1-16/17-32] button’s indicator is not lit. If
the indicator is lit, press [1-16/17-32] to turn it off.
16. Press [ ]/[ ]/[ ]/[ ] to move the cursor to
the parameter you wish to set, and rotate the VALUE
dial, or press [INC] or [DEC] to set the value as follows.
Part Output Part Chorus Part Reverb
Assign Send Level Send Level
500
The output level can be set to any value you wish other than
0.
17. Press [EXIT] to return to the PERFORM PLAY page.