Yamaha LSP Music Mixer User Manual


 
LS9 Editor Owner’s Manual
14
D Ø (Phase)
Inverts the phase of the signal after AD conversion.
E HPF (High Pass Filter)
Switches the high pass filter on/off. You can drag the numeric value up or down to edit
the cutoff frequency.
F INS (Insert)
Enables/disables the insert-in. (INPUT CH 1–32 only)
G D. OUT (Direct out)
Enables/disables the direct output.
H EQ (Equalizer)
Switches the EQ on/off. The graph immediately below the button shows the approxi-
mate response of the EQ. You can drag within the graph to edit the response of the EQ.
To reset the EQ to flat response, hold down the <Ctrl>(< >) key of your computer
keyboard and click the graph (The HPF setting will remain).
I DYN1/DYN2 (Dynamics 1/Dynamics 2)
Turns the two dynamics processors on/off.
If Gate is assigned (Dynamics 1 only), the status of the gate is shown immediately below
the button.
If something other than Gate is assigned, a GR meter is shown immediately below the
button, and the amount of gain reduction is shown while this is on.
The type for each dynamics processor can be selected in the Selected Channel window.
J MIX SEND
The bar graphs located immediately below the button
show the send level of the signals sent from the INPUT
CH to VARI type MIX buses. You can also drag the bar
graph to left or right to set the send level. While you
drag the bar graph, the send level is shown in the
numerical display area for PAN/TO STEREO MONO
(
K).
You can set the minimum value (– dB) by holding
down the <Ctrl>(< >) key of your computer key-
board and clicking the bar graph, or set the nominal
value (0.00 dB) by holding down the <Ctrl>(< >)
key and <Shift> key and clicking the bar graph.
The bar graph display will change according to the
send position (pre/post) and on/off status of the signal
sent from the INPUT CH to the MIX buses.
To switch a send on/off, click the channel number
located at the left of the bar graph.
For FIXED-type MIX buses, the bar graph is
fixed at nominal level (0 dB), and only the on/
off status is shown.
Gate status
indication
On/off status On On On Off
Open/closed
status
Closed Open Open
Remarks
Gain reduction amount
is 30 dB or more
Gain reduction
amount is 0–30 dB
Gain reduction
amount is 0 dB
L
M
N
P
O
Q
K
J
4
6
7
8
5
9
• Pre/on (green)
• Pre/off (green)
• Post/on (yellow)
• Post/off (yellow)
NOTE