Extron electronic DMP 64 Music Mixer User Manual


 
Digital I/O Ports
The DMP64 provides six digital I/O ports that can trigger external events from DMP64
actions, or allow external events to trigger DMP64 actions. The DSPConfigurator
software provides pre-configured scripts with a fixed set of common trigger and event
combinations. When selected, the script is compiled and placed onto the File
Management system of the device. For more advanced or custom scripts, contact an
Extron Electronics Applications Engineer.
When no scripts are active, the digital I/O ports default to DI (digital input) and inactive
(‘Logic Hi’
+5VDC). The DI detects a Logic Hi as +5 VDC and LogicLow (active) as less
than +1 VDC.
A DO (digital output) sends a Logic Lo as less than +1 VDC and a Logic Hi as +5VDC.
For every script that involves a DO, two versions are available to provide either a Logic Hi
or a Logic Lo response to any action. The alternate script is designated as Reverse DO.
To build a script and place it into the DMP64 File Management system:
1. From the tools menu, click Configure Digital I/O>Build Digital I/O
Configuration.
2. This brings up a dialog that allows selection from a list of pre-configured scripts.
3. Select a script from the Select a Digital I/O Configuration section. The
eventdescription section describes the script and how the digital I/O ports act while
the script is running. Highlight the desired script, then click OK.
4. A dialog box appears, verifying the file has been successfully uploaded to the device.
NOTE: When performing this procedure in Emulate mode, the connection
dialog appears between step 3 and step 4. DSP Configurator connects and
then disconnects during the procedure, returning to Emulate mode when the
Digital I/O has been configured.
DMP64 • Software Control 75