Extron electronic DMP 64 Music Mixer User Manual


 
Selecting Live Mode and Pushing or Pulling Data
To switch from Emulate mode to Live mode:
1. Select the desired connection to the DMP64 and make the proper connections.
NOTE: Extron recommends connection with the Ethernet LAN port when using
DSPConfigurator.
2. Click the Mode Live button, (see figure 52,
b
). The Communication Type
selection window appears.
or
or
Extron USB device
2
3
4a
4b
4c
5a
5b
5c
3
6a
6b
3
Figure 52. Selecting Live Mode
3. Click one of the following tabs:
• TCP/IP for connection using the LAN port (preferred) — proceed to step 4,
• RS-232 for connection using either of the rear panel RS-232 ports — proceed to
step 5, or
• USB for connection using the front panel configuration port — proceed to step6.
4. If TCP/IP is selected in step 3:
a. Observe the IP Address field in the IP connection window. The field displays the
last IP address entered.
• If the IP address is correct, proceed to step 4b.
• If the IP address is not correct, either click in the IP Address field and enter
the IP address or click the drop-down arrow to open a list and select from a
recently used address. Proceed to step 4b.
NOTE: If the local system administrators have not changed the
address, the factory-specified default, 192.168.254.254, is the correct
value for this field.
b. If the device is password protected, click in the Password field and enter the
appropriate administrator password.
c. Click OK.
The Synchronize with Device dialog box (see figure 53 on page 79) opens.
Proceed to step 7.
DMP64 • Software Control 77