Extron electronic DMP 64 Music Mixer User Manual


 
SIS Programming
and Control
This section describes SIS programming and control of the DMP64, including:
• Connection Options
• Host-to-device Communications
• Command and Response Table for Basic SIS Commands
• Command and Response Tables for DSP SIS Commands
• Special Characters
Connection Options
The DMP64 Digital Matrix Processor can be remotely connected via a host computer or
other device (such as a control system) attached to the rear panel RS-232 port or LAN
port, or the front panel USB Config port.
The DMP64 can be set up and controlled using SIS commands, embedded web pages,
or DSPConfigurator software. See Installation on page5 for pin assignments
and details on the configuration and control port connections. For information on
DSPConfigurator, see DMPSoftware on page14, and for the embedded web pages,
see HTML Operation on page120.
SIS commands can be executed using the Extron Electronics DataViewer program, found
on the Software Products DVD included with the product.
DMP64 RS-232 protocol:
• 38400 baud • no parity • 1 stop bit
• 8 data bits • no flow contro
NOTE: Both rear panel configuration ports require 38400 baud communication. This
is a higher speed than many other Extron products use. When using HyperTerminal
or a similar application, make sure the PC or control system connected to these
ports is set for 38400 baud.
For additional details on connecting the RS-232 port, see RS-232 Ports on page93.
USB port details:
The Extron USB driver must be installed before the USB port can be used (see Install the
USB Driver on page17).
LAN port defaults:
DMP64 IP address: 192.168.254.254
gateway IP address: 0.0.0.0
subnet mask: 255.255.0.0
DHCP: off
DMP64 • SIS Programming and Control 92