Korg MS2000 Musical Instrument User Manual


 
22
5. Specify time-varying change in the tone
Use EG 1 to create time-varying change in the cutoff fre-
quency (FILTER “Cutoff”).
If you wish to use the front panel knobs to adjust the
EG 1 parameters, use the SEQ EDIT [SELECT] key to
make the SEQ 1–3 LED’s go off.
a. Adjust the speed at which the tone will change dur-
ing the attack
Rotate the EG 1 [ATTACK] knob.
The LCD screen will show Page 10A: EG 1 “Attack.”
Rotating the knob toward the right will cause the tone to
change more slowly, and rotating it toward the left will
cause the tone to change instantly.
If rotating the knob does not produce an effect, try
adjusting the FILTER [EG 1 INT] knob, or make sure
that the SEQ EDIT SEQ 1–3 LED’s are dark. If these
LED’s are lit, it is not possible to edit the EG or LFO.
The knobs will function to edit the sequence data.
b. Adjust the speed at which the tone will change dur-
ing the decay
Rotate the EG 1 [DECAY] knob.
The LCD screen will show Page 10B: EG 1 “Decay.”
Rotating the knob toward the right (increasing the
value) will cause a longer decay time until the sustain
level is reached.
c. Adjust the brightness of the sustained sound
Rotate the EG 1 [SUSTAIN] knob.
The LCD screen will show Page 10C: EG 1 “Sustain.”
The change in brightness produced by the [SUSTAIN]
knob will depend on the setting of the [EG 1 INT] knob.
d. Adjust the speed at which the tone will change after
the note is released
Rotate the EG 1 [RELEASE] knob.
The LCD screen will show Page 10D: EG 1 “Release.”
Rotating the knob toward the right will make the sound
change more slowly, and rotating it toward the left will
make it change instantly.
6. Adjust the output of the timbre
a. Adjust the volume of the timbre
Rotate the [LEVEL] knob.
The LCD screen will show Page 09A: AMP “Level.”
If the volume changes over time, this level will be the
maximum level that occurs during the change in vol-
ume.
b. Adjust the output panpot (stereo position)
Rotate the [PAN] knob.
The LCD screen will show Page 09B: AMP “Panpot.”
When the knob is in the center (CNT), the output will be
centered.
c. Select the envelope source for the volume
Press the [EG 2 /GATE] key.
Each time you press the key, the envelope source will
change.
If you want the volume change over time, select EG 2
([EG 2/GATE] key LED dark).
If you want the volume to sound at a fixed level, as on
an organ, select GATE ([EG 2/GATE] key LED lit).
a: Attack Time c: Sustain Level
b: Decay Time d: Release Time
Time
Note on
Note off
Cutoff
a
c
d
b
a b c d
10A EG 1
Attack: 000
10B EG 1
Decay: 030
10C EG 1
Sustain: 060
10D EG1
Release: 000
a
b
c
d
09A AMP
Level: 127
09B AMP
Panpot: CNT