Korg MS2000 Musical Instrument User Manual


 
Parameter Guide
57
Arpegio
The pedal switch will function as an arpeggiator on/off
switch.
C: A.Switch..........................................................[–, +]
Select the polarity of the pedal switch that is connected.
Set this to “” if you are using a Korg PS-1 pedal switch or if
you are not using a pedal switch.
D: A.SwMode ...................................... [UnLatch, Latch]
Specify how a connected pedal switch will turn on/off.
(With the factory settings, this is Unlatch.)
UnLatch
The switch will be on only while it is being pressed.
Latch
The switch will alternate between on and off each time it is
pressed.
A: User Scale
Specify the user scale.
For each pitch in the octave (C–B), you can adjust the pitch in
a range of –100 — +100 cents.
The entire keyboard will use this scale if you set LCD Edit
mode Page 01: COMMON “Scale” to User Scale.
Key ....................................................................[C...B]
Select the note whose pitch you wish to adjust.
Detune ...................................................[–100...+100]
Adjust the pitch in one-cent units, relative to the equal tem-
perament as 0.
A setting of +100 raises the pitch a semitone (+100 cents)
above standard pitch.
A setting of –100 lowers the pitch a semitone (–100 cents)
below standard pitch.
Here you can set the active range of the MS2000/MS2000R’s
controllers or a connected pedal switch or pedal. Make these
settings if operating a controller or pedal does not produce
the desired result.
A: AS
Make settings for a switch connected to the MS2000/
MS2000R.
Turn the connected switch on/off, and then press the [+/
YES] key.
B: AP
Set the active range of a pedal connected to the MS2000/
MS2000R.
Move the connected pedal through its maximum range of
movement, and then press the [+/YES] key.
C: BW (MS2000 only)
Set the active range of the MS2000’s pitch bender.
Move the pitch bender through its maximum range of move-
ment, return it to the center, and then press the [+/YES] key.
D: MW (MS2000 only)
Set the active range of the MS2000’s modulation wheel.
Move the modulation wheel through its maximum range of
movement, and then press the [+/YES] key.
If you do not perform these settings correctly, the dis-
play will indicate “Invalid Data” when you press the
[+/YES] key. If this occurs, make the setting once
again.
You must perform the Write operation for CALIB set-
tings just as for other Global parameters. If you fail to
perform the Write operation, the settings will revert to
their previous values (p.30).
Page7: USER SCALE
Page8: CALIB
7A USER SCALE
KEY[C ]:+000
Key
Detune
Global parameters