SentrySafe SPD 5.5.5 Recording Equipment User Manual


 
Sample Sequencer
Operation
To Program:
Press the DISPLAY key to select desired function. To select desired POINT number
for the low and high alarms press the NEXT key.
Press PROGRAM. The programming arrows light up and the current programmed
value is displayed.
Starting at the right digit, pressing the key immediately above the up arrow
(DISPLAY) causes the digit to increment. Press repeatedly until the desired digit is
displayed.
Each pressing of the key above the left arrow (NEXT) shifts the active digit one to
the left. The active digit may be incremented using the aforementioned up arrow
key.
Each pressing of the key above the right arrow key (ALARM RESET) shifts the active
digit one to the right.
Pressing the PROGRAM key again:
Turns the arrow lights off.
Saves the value in permanent memory.
Returns the Sample Sequencer to its normal display.
The newly programmed values are active on the next cycle. Press
START/RESET to restart the sequencer using the new values.