SentrySafe SPD 5.5.5 Recording Equipment User Manual


 
Sample Sequencer
Appendix G
Trouble-shooting: If the Sample Sequencer display doesn't illuminate, check the fuse (F1)
on the I/O board. If shorted out, replace the with the 3 Amp fuse included in retrofit kit. (See
step 6 above.) If the display still doesn't light, verify you are using the new 3 Amp power
supply included in your retrofit kit. (See step 5, above.) Using a meter, one should measure
a minimum 6 VDC across terminals +6 and - on J1 of the I/O board. The old power supply is
inadequate when using plug-in track & hold.
13. Note: Your plug-in track & hold board has a total of four independent outputs and is factory-
calibrated.
See Appendix F if you desire to reconfigure your board to produce two independent outputs
per point with a maximum two points per plug-in track & hold board.