![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/3/6d/36db2b94-b5fe-4d9d-af19-800fbd7667e8/36db2b94-b5fe-4d9d-af19-800fbd7667e8-bg26f.png)
1-12
To do… Use the command… Remarks
Configure the maximum
number of history records that
can be saved
history-records number
Optional
By default, the maximum
number is 50.
Configure the automatic test
interval
frequency interval
Optional
By default, the automatic test
interval is zero seconds,
indicating no automatic test will
be made.
Configure the probe timeout
time
timeout time
Optional
By default, a probe times out in
three seconds.
Configure the type of service
tos value
Optional
By default, the service type is
zero.
Start the test
test-enable
Required
Display test results
display hwping results
[ admin-name operation-tag ]
Required
You can execute the command
in any view.
7) Configuring TCP test on HWPing client
Follow these steps to configure TCP test on HWPing client:
To do… Use the command… Remarks
Enter system view
system-view
—
Enable the HWPing client
function
hwping-agent enable
Required
By default, the HWPing client
function is disabled.
Create a HWPing test group
and enter its view
hwping administrator-name
operation- tag
Required
By default, no test group is
configured.
Configure the destination
address
destination-ip ip-address
Required
This IP address and the one
configured on the HWPing
server for listening services
must be the same.
By default, no destination
address is configured.