2-7
2) Enable Monitor Link on Switch C and Switch D and enable the function of processing flush
messages received from VLAN 1. Perform the following configuration on Switch C. The operation
procedure on Switch D is the same as that performed on Switch C.
# Enter system view.
<SwitchC> system-view
# Create Monitor Link group 1 and enter Monitor Link group view
[SwitchC] monitor-link group 1
# Configure GigabitEthernet 1/0/1 as the uplink port of the Monitor Link group and GigabitEthernet 1/0/2
and GigabitEthernet 1/0/3 as the downlink ports.
[SwitchC-mtlk-group1] port GigabitEthernet 1/0/1 uplink
[SwitchC-mtlk-group1] port GigabitEthernet 1/0/2 downlink
[SwitchC-mtlk-group1] port GigabitEthernet 1/0/3 downlink
# Return to system view. Enable the function of processing flush messages received from VLAN 1 on
GigabitEthernet 1/0/2 and GigabitEthernet 1/0/3.
[SwitchC-mtlk-group1] quit
[SwitchC] smart-link flush enable control-vlan 1 port GigabitEthernet 1/0/2 to
GigabitEthernet 1/0/3
3) Enable the function of processing flush messages received from VLAN 1 on GigabitEthernet 1/0/10
and GigabitEthernet 1/0/11 of Switch E.
# Enter system view.
<SwitchE> system-view
# Enable the function of processing flush messages received from VLAN 1 on GigabitEthernet 1/0/10
and GigabitEthernet 1/0/11.
[SwitchE] smart-link flush enable control-vlan 1 port GigabitEthernet 1/0/10 to
GigabitEthernet 1/0/11