75
VR800 Owner’s Manual (Saving and Loading Song Data)
Outline of the save/load operation
The VR800 has a Save/Load function for song data, which enables you to save the recorded song data (including
SETUP data) to a connected backup media, such as a DAT machine, back-up SCSI disk or adat. You can also load
the saved data from a DAT, back-up SCSI disk or adat to the current drive disk in the VR800. You can save and
load one Program at a time to and from a DAT, adat, or SCSI drive.
The following diagram shows different methods (depending on the current drive type) for saving data to con-
nected media, and how to load data to the VR800. Select the appropriate connections depending on the type of
connected media.
Saving and Loading Song Data
Using a SCSI drive as the current drive:
The connection should follow one of these cases:
* Transferring data between SCSI drive-1 and SCSI drive-2
* Transferring data between SCSI drive-1 and a DAT (See “Note.”)
* Transferring data between SCSI drive-1 and an adat (See “Note.”)
Note:
You can save and load data between two SCSI drives,
regardless of the recording mode used for the disks.
When saving a multiple number of program data in one disk,
they must definitely be of the same format.
Note:
You can save and load data to and from a DAT or adat
only if the current drive is a SCSI fixed disk and it has been
formatted in Master 8ch mode. You cannot perform the save/
load operation if the disk has been formatted in Master 4ch mode
or ADAC 8ch mode. (However, only in the case of save/load by
DAT, the master 4ch mode disk can also be used.)
Note:
Be sure to set the ID number for a backup SCSI drive to
“6.”
Using an 3.5-inch internal E-IDE hard disk as the current drive:
The connection should follow one of these cases:
* Transferring data between a 3.5-inch E-IDE hard disk and a SCSI drive
* Transferring data between a 3.5-inch E-IDE hard disk and a DAT (See “Note.”)
* Transferring data between a 3.5-inch E-IDE hard disk and an adat (See “Note.”)
Note:
You can save and load data to and from a DAT or adat only
when the current drive has been formatted in Master 8ch mode. You
cannot perform the save/load operation if the disk has been formatted
in Master 4ch mode or ADAC 8ch mode. However, you can save and
load data to and from a SCSI drive, regardless of the recording mode
used for the disk.
Note:
If you are using an 3.5-inch E-IDE hard disk as the current drive,
you can connect only a SCSI backup disk to the SCSI terminal on the
VR800 (the ID number should be set to “6.”). If you connect a SCSI drive
disk set up as a current drive disk (the ID is set to any number other than
“6”) and you turn on the power to the drive, the VR800 will recognize this
SCSI drive as the current drive.
<Notes on connection>
If the connected DAT (preferably a professional model) features sync operation with external clock and its “INPUT (or EXTERNAL
SYNC)” sync mode switch is set to OPTICAL, trying to load data with both digital I/Os connected as shown in the diagram may
cause a digital clock loop to form and loading may fail.
In this case, set the sync mode of the DAT to INTERNAL, or disconnect the optical cable from the DATA OUT of the VR800 before
loading data. This type of problem will not occur during the save operation since the DATA IN connector of the VR800 is not
effective.
VR800
SCSI drive-1
DAT
adat
Current Drive
SCSI drive
SCSI
DATA IN
DATA OUT
Current drive
Back-up drive
SCSI drive-2
VR800
SCSI drive
DAT
adat
Current Drive
3.5-inch E-IDE hard disk
SCSI
DATA IN
DATA OUT
Back-up drive