SYSTEM FUNCTIONS 8-9
t
DEEP TECH NOTE!
Remote control values for LCD contrast and backlighting are only vaguely
related to the 0-100% settings in the System menu.
level none Display current encoder input & decoder
output level, for testing the meter
calibration.
log [<GEN> <SYS> <ISDN> <IMON>
<DEB> <off>]
Used for remote debugging. During a
support call, we may ask you to send this
command and tell us what the result is.
login [<?> |
<password>]
Example login user ¶
Display current security level.
Unlock at the security level associated with
this password.
Opens communication at User level.
logout none Log out from ZephyrExpress control
system.
metertest none
[<0...9 0...9 0...9
0...9>]
Resets front panel level meters to normal
operation after a test.
Turns on the four level meter LEDs up to
the number indicated, for lamp testing.
If you’re going to specify an argument, you
must supply numbers for all four meters:
metertest 9 9 ¶ would be rejected.
Example metertest 9 9 9 9 ¶ Lights up all four metersas if they were
indicating a signal at -10dB.
mic <1|2|both> [<phant|highf>
<on|off>] |
[<hisens|medsens|losens|
linesense>]
Example
mic 2 highf on ¶
Switches microphone phantom power or
highpass filter on or off, or sets mic
sensitivity.
Turns on the highpass filter for mic 2.
mop none
[<l3du|l3st|l3jo|g722|
l2mo64|l2mo128|l2du|
l2jo|->]
[<l3st|l3mo|g722|l2|->]
Displays the current codec mode (using the
codes below).
Sets the transmit mode to L3-dual or L3-
stereo or L3-joint or G.722 or L2-mono64
or L2-mono128 or L2 dual or L2-joint. If
the parameter is sent as “–”, the current
transmit mode is kept.
Sets the receive mode to L3-stereo or L3-
mono or G.722 or L2. If the parameter is
sent as “–”, the current receive mode is