Cisco Systems 15501 Musical Instrument Amplifier User Manual


 
4-19
Cisco ONS 15501 User Guide
78-14134-02, Release 2.0
Chapter 4 Command Reference
inpwr
inpwr
To display the measured optical input power, use the inpwr command.
inpwr
Syntax Description
Defaults None
Command Types Does not change configuration
Command Modes User password protected
Command History
Usage Guidelines The value for optical input power is displayed in dBm.
Examples The following example shows how to display the optical input power.
edfa > inpwr
-46.03 (dBm)
Related Commands
This command has no other arguments or keywords.
Release Modification
EDFA 1.0 This command was introduced.
Command Description
inpwrmean Displays the optical input alarm mean level.
inpwrtrig Displays the optical input alarm trigger level.
resetmeantrig Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturers default settings.
setinpwrmean Sets the optical input alarm mean level.
setinpwrtrig Sets the optical input alarm trigger level.