setgainmean
setgainmean
To modify the signal gain and alarm mean, use the setgainmean command.
setgainmean mean
Syntax Description
Defaults 17.5 dB
Command Types Changes configuration
Command Modes Master password protected
Command History
Usage Guidelines The signal gain and alarm mean is measured in dB. The system accepts a minimum value of 7 dB and a
maximum value of 17.5 dB. If a value entered falls outside of this acceptable range, the command will
be ignored and have no effect.
Examples The following example shows how to modify the signal gain and alarm mean.
edfa > setgainmean 17.00
Related Commands
mean Specifies the desired signal gain and alarm mean.
Release Modification
EDFA 1.0 This command was introduced.
Command Description
gain Displays the measured optical signal gain.
gainmean Displays the configured signal gain and alarm mean level.
gaintrig Displays the gain alarm trigger level.
resetmeantrig Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturers default settings.
setgaintrig Sets the gain alarm trigger level.