Cisco Systems 15501 Musical Instrument Amplifier User Manual


 
4-53
Cisco ONS 15501 User Guide
78-14134-02, Release 2.0
Chapter 4 Command Reference
status
status
To display the measured, alarm mean and alarm trigger values for input power, internal case temperature,
optical gain and output signal power, as well as the measured values for optical output power, use the
status command.
status
Syntax Description
Defaults None
Command Types Does not change configuration
Command Modes User password protected
Command History
Examples The following example shows how to display the status of the system.
edfa > status
===============================================================================
Status Measured Mean Trigger
Input Optical Power NORMAL -15.84 (dBm) -10.00 (dBm) 15.00 (dBm)
Optical Gain NORMAL 6.99 (dB) 7.00 (dB) 0.50 (dB)
Optical Output Power -8.72 (dBm)
Output Signal Power NORMAL -8.77 (dBm) -6.00 (dBm) 18.00 (dBm)
Power Supply 1 OUT-OF-RANGE -3.48 (vDC)
Power Supply 2 NORMAL -49.70 (vDC)
Pump Laser GOOD
Temperature NORMAL 29.53 (C) 25.10 (C) 29.90 (C)
===============================================================================
This command has no other arguments or keywords.
Release Modification
EDFA 1.0 This command was introduced.