setoutsigpwrmean
setoutsigpwrmean
To set the output signal alarm mean level, use the setoutsigpwrmean command.
setoutsigpwrmean mean
Syntax Description
Defaults 2.00 dBm
Command Types Changes configuration
Command Modes Master password protected
Command History
Usage Guidelines The output signal alarm mean is measured in dBm. See Table 1-2 on page 1-2 for the minimum and
maximum values. If a value entered falls outside of this acceptable range, the command will be ignored
and have no effect.
Examples The following example shows how to set the output signal alarm mean level.
edfa > setoutsigpwrmean 1.00
Related Commands
mean Specifies the desired output signal alarm mean level.
Release Modification
EDFA 1.0 This command was introduced.
Command Description
outsigpwr Displays the calculated output signal power.
outsigpwrmean Displays the output signal alarm mean level.
outsigpwrtrig Displays the output signal alarm trigger level.
resetmeantrig Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturers default settings.
setoutsigpwrtrig Sets the output signal alarm trigger level.