Cisco Systems 15501 Musical Instrument Amplifier User Manual


 
4-42
Cisco ONS 15501 User Guide
78-14134-02, Release 2.0
Chapter 4 Command Reference
setinpwrmean
setinpwrmean
To set the optical input alarm mean level, use the setinpwrmean command.
setinpwrmean mean
Syntax Description
Defaults 20.00 dBm
Command Types Changes configuration
Command Modes Master password protected
Command History
Usage Guidelines The optical input alarm mean is measured in dBm. See Table 1-2 on page 1-2 for the minimum and
maximum values. If a value entered falls outside of this acceptable range, the command will be ignored
and have no effect.
Examples The following example shows how to set the optical input alarm mean level.
edfa > setinpwrmean -28.00
Related Commands
mean Specifies the desired optical input alarm mean level.
Release Modification
EDFA 1.0 This command was introduced.
Command Description
inpwr Displays the measured optical input power.
inpwrmean Displays the optical input alarm mean level.
inpwrtrig Displays the optical input alarm trigger level.
resetmeantrig Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturers default settings.
setinpwrtrig Sets the optical input alarm trigger level.