settempmean
settempmean
To modify the internal case temperature alarm mean level, use the settempmean command.
settempmean mean
Syntax Description
Defaults 30° C
Command Types Changes configuration
Command Modes Master password protected
Command History
Usage Guidelines The internal case temperature mean is measured in degrees Celsius. See Table 1-2 on page 1-2 for the
minimum and maximum values. If the value falls outside the acceptable range, the command will be
ignored and there will be no side effect.
Examples The following example shows how to modify the internal case temperature alarm mean level.
edfa > settempmean 29.00
Related Commands
mean Specifies the desired internal case temperature alarm mean level.
Release Modification
EDFA 1.0 This command was introduced.
Command Description
resetmeantrig Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturers default settings.
settemptrig Sets the internal case temperature alarm trigger level.
temp Displays the internal case temperature level.
tempmean Displays the internal case temperature alarm mean level.
temptrig Displays the internal case temperature alarm trigger level.