103
Changing the initial setting (SETUP mode)
Setting MIDI sync output signal (“Sync Out ?” menu)
The “Setting MIDI sync output signal” menu enables you to select the type of MIDI sync signals output from the
MIDI OUT connector on the rear panel of the FD-8 to an external MIDI device.
The options are MIDI clock & Song Position Pointer, or MTC (MIDI time code). Select an appropriate option
depending on the type of signal supported by the connected MIDI device.
If you select MIDI clock & Song Position Pointer, first you need to set the time signatures and tempo as described
previously. If you select MTC, you first need to set the MTC frame rate, the MTC offset time, and the MTC offset
mode as described later.
• Initial setting: [cLK] (clock & Song Position Pointer)
• Option: [cLK] (clock & Song Position Pointer), [Mtc] (MIDI time code), [oFF] (no output)
* You can set the parameters for each Program individually.
* The settings can be saved and loaded as part of the song data.
* The settings are maintained after you turn off the power to the unit.
Setting MIDI sync signal
1. While the FD-8 is stopped, press the SETUP key to
enter SETUP mode.
2. Rotate the JOG dial to select [Sync Out ?] ([?]
flashes.), then press the EXECUTE/YES key.
The currently-selected MIDI sync signal type appears on
the display.
Press the EXECUTE/YES key to turn off the flashing [?]
indication. The MIDI sync signal type indication flashes,
and the indicator flashes indicating the SYNC OUT setting.
The initial setting is [cLk] as shown below.
3. Turn the JOG dial to select the desired MIDI sync
signal.
Setting this parameter to [cLK] (initial setting) will select
MIDI clock & Song Position Pointer.
Setting the parameter to [Mtc] will select MIDI time code.
With the [oFF] setting, no MIDI sync signal will be output.
4. Press the EXECUTE/YES key.
The selected MIDI sync signal type is stored, and the FD-
8 returns to the display with the flashing [?] indicator as
shown in step 2.
Each option appears on the display as follows.
When [cLK] is selected:
When [Mtc] is selected:
When [oFF] is selected:
To cancel the setting operation, or to restore a setting
obtained prior to the EXECUTE/YES key press, press the
STOP button or the EXIT/NO key. Each time you press
one of these keys, the FD-8 returns to the previous
hierarchy level of the menu, and finally exits SETUP mode
and displays the previous Time Base.
SYNC OUT
CLK
SYNC OUT
MTC
SYNC OUT
SETUP
DRIVE
AUTO A.PUNCH
SYNC OUT
CLK
SCSI
44.1kHz
SETUP
DRIVE
AUTO A.PUNCH
SYNC OUT
CLK
SCSI
44.1kHz