72
1. Basic operations
1-13. Waveform monitor settings
WFM (waveform monitor) settings
1Press the [WFM/VECT] button among the display mode
buttons to display the waveform monitor on the built-in
display.
2Press the s button to light its indicator, and display the
Config menu.
3Use [F1] to display the WFM sub menu.
4Use [F2] to select the method to be used to display the
signal waveforms using the Style item.
Parade The signal waveforms are arranged and
displayed.
Overlay The signal waveforms are superimposed onto
each other and displayed.
5Use [F3] to select the signals whose waveforms are to
be displayed using the Mode item.
YPbPr Waveforms of the Y, PB and PR signals are
displayed.
RGB Waveforms of the R, G and B signals are
displayed.
Y Waveforms of the Y signal only are displayed.
VECTOR (vectorscope) settings
1Press the [WFM/VECT] button among the display mode
buttons to display the vectorscope on the built-in display.
2Press the s button to light its indicator, and display the
Config menu.
3Use [F1] to display the Vector sub menu.
4Use [F2] to select the color bar reference marker using
the Bar Target item.
75% The 75% color bar reference marker is
displayed.
100% The 100% color bar reference marker is
displayed.