Chapter 4. Editing a Sample
7.
Press [F3] (TRUNC). A message “Truncate, Are You Sure?” will ask you whether you are sure you want to
truncate (delete) the portions of the sample that are outside the specified Start and End points. To truncate
the sample, press [F3 (EXEC). If you decide to cancel, press [F2] (CANCEL).
Executing the Truncate operation will conserve sample memory, increasing the sampling time that
remains.
Once you execute Truncate, you cannot return to the Start and End points prior to execution.
8.
Press [EXIT] to return to the Play screen.
1.
Go to the Play screen (p. 15).
2.
Hold down [FUNC] and press pad [15] (BPM SYNC) to get the BPM
SYNC screen.
The number of the pad you press in step 3 is shown in the upper left of
the screen.
(Example) PAD 8-1: pad bank 8, pad number 1
The lower left of the screen shows the “Play Type” (p. 50) and BPM.
3.
Press the pad whose sample settings you want to edit.
If you want to select a sample from a different pad bank, switch the pad bank (p. 23) and then press a pad to select
a sample.
You can’t edit samples of a pad bank that is protected (p. 31).
4.
Turn the VALUE dial or use [DEC][INC] to change the “Type” setting.
5.
If you want to change the BPM for a sample of a different pad, repeat steps 3 and 4.
Pads set to a setting of other than OFF in step 4 will be highlighted.
By pressing [F1] (RESET) you can set “Type” to
OFF
for all pads in the currently selected pad bank.
The BPM of a sample can be adjusted in a range of 0.5–1.3 times. If synchronization would cause the
sample BPM to exceed this range, the sample BPM will be doubled or halved to stay within the
range.
Changing the BPM may cause noise to be more noticeable.
The BPM cannot be changed if the sample is shorter than approximately 200 ms.
The BPM cannot be changed if the “Play Type” (p. 50) is SINGLE.
The BPM cannot be changed for samples set to Reverse playback (p. 50).
6.
Press [EXIT] to return to the Play screen.
Changing a Sample’s BPM (Tempo)
Parameter
Value Explanation
Type
OFF
The sample will play at its own BPM.
SEQ
The sample will synchronize to the BPM of the song or pattern.
Press [ ] to move to the line below, and turn the VALUE dial or use [DEC][INC] to
select ALWAYS or PLAY ONLY.
ALWAYS
: The sample will synchronize whether during playback or while stopped.
PLAY ONLY
: The sample will synchronize only during playback.
FIX
Specify an individual BPM for the sample.
Press [ ] to move to the line below, and turn the VALUE dial or use [DEC][INC] to
change the BPM value (40.0–200.0).