Formant ★◆
This sets the range of change in vocal quality (formant).
Value: -63– +63
Formant KF (Formant Key Follow)
Specifies the amount by which the formant value will be affected by
the key you play.
Value: -200– +200
Energy
Specifies how much the fundamental pitch will be emphasized in
order to make the sound more well-defined. Set this to “OFF” if you
do not want to use the Energy parameter.
Value: OFF, 1–127
Fmt LFO Depth (Formant LFO Depth) ★◆
Specifies how deeply the LFO will affect formant.
Value: -63– +63
In this screen you can make settings for the envelope that affects
the formant. For details on envelope settings, refer to “Making
Envelope Settings” (p. 48).
OSC TVA
fig.03-19_50
Level ★◆
Specifies the volume of the oscillator.
Value: 0–127
Level KF (Level Key Follow)
Use this parameter if you want the volume of the oscillator to change
according to the key that is pressed. Relative to the volume at the C4
key (center C), positive (+) settings will cause the volume to rise for
notes higher than C4, and negative (-) settings will cause the volume
to fall for notes higher than C4. Larger settings will produce greater
change.
Value: -200– +200
Level LFO Dp (Level LFO Depth)
Specifies how deeply the LFO will affect the volume of the oscillator.
Value: -63– +63
In this screen you can make settings for the envelope that affects
the sub TVA. For details on envelope settings, refer to “Making
Envelope Settings” (p. 48).