Fostex VF-16 Recording Equipment User Manual


 
85
flashing
flashing
* If you load data to a program in which data is
already recorded, the newly loaded data overwrites
the current data track by track.
Consequently, on each overwritten track, the loaded
data becomes valid while the current data is erased.
4. Use the [JOG] dial to select the program to which data
is loaded and press the [ENTER/YES] key.
The display shows the screen for selecting tracks to be
loaded.
5. Select tracks to be loaded.
Press the [REWIND] or [F FWD] key to move the flashing
field between "From" and "To".
Use the [JOG] dial to set the track number for the
flashing field. For the "From" field, you can select from
1, 9 and 17. For the "To" field, you can select from 8,
16 and 24.For example, if you select "From 1 to 24",
data for all tracks (1 to 24) will be loaded.
6. After selecting tracks, press the [ENTER/YES] key
again.
The display shows something like the one below. A load
destination program (existing or new program) to which
the data is loaded and tracks to be loaded are shown,
while "Sure?" flashes.
<Note>
In the above step, if the VF-16 does not lock to the digital
signal from the external digital device, the following
warning message appears on the display.
This indicates that the VF-16 does not receive a correct
digital signal (S/PDIF or adat signal). So check the cable
connection and the digital output settings of the external
digital device.
7. When the VF-16 is locking to the digital input signal,
press the [ENTER/YES] key.
The display shows "Play Start Player!."
8. Start playback of the player.
After reading the pilot signal recorded when saving the
data, the data starts loading automatically.
When starts loading, the display shows something like
the one below, in which "Wait time" starts counting
down.
Using the S/PDIF signal, data is loaded in 2-track unit.
While loading, the indicators on [CH STATUS/CH SEL]
keys for channels 1 and 2 flash, while the input levels
are displayed by level meters 1 and 2.
Using the adat signal, data is loaded in 8-track unit.
While loading, the indicators on [CH STATUS/CH SEL]
keys for channels 1 through 8 flash, while the input
levels are displayed by level meters 1 and 8.
When the data loading is completed, "Completed!"
appears on the screen.
<Note>
If you quit loading before completing, the loaded data
is invalid.
9. Stop the external DAT (or adat) machine.
10. Press the [EXIT/NO] key (or the [STOP] key) repeatedly
until exiting the Setup mode.
To cancel each operation or to return to the previous
screen before pressing the [ENTER/YES] key, press the
[EXIT/NO] key (or the STOP key). Each press of the key
returns to the previous screen and finally exits the Setup
mode.