Table 1-1 Format of a basic command
Command Format Description
<command>[<number>] In the command format, <command> indicates a single
letter (A–Z) or the & symbol plus a single letter.
In the command format, <number> indicates a decimal
number with one digit or multiple digits. The digit 0 in the
forefront of <number> can be ignored.
Note:
If a basic command that is allowed to contain <number> does not contain <number>, the
default value of <number> is used in the command.
If a basic command that is not allowed to contain <number> contains <number>, "Operation
not allowed" is returned.
An S register command consists of the letter S and a decimal number, which is called
the parameter number of the register. An S register command can be in the format of
read command and write command.
Table 1-2 describes the format of an S register
command.
Table 1-2 Format of an S register command
Command Format Description
Read
command
S<parameter
number>?
Returns the ASCII code of characters currently saved
in the S register. The ASCII code is expressed by a
3-digit decimal number. The digit 0 is added in the
front of the number in case of insufficient digits.
Write
command
S<parameter
number>=<value>
Replaces the characters saved in the S register with
the characters related to the value of <value>.
Note:
If the parameter number of the register is not identified, this indicates that the command does
not exist. In this case, ERROR is returned.
All extended commands start with the + symbol. Vendor-defined commands start with
a special symbol such as ^ and %. In this document, all vendor-defined commands
start with the ^ or \ symbol. Extended and vendor-defined commands are further
categorized into action commands and parameter commands.
Table 1-3 describes
the types and formats of extended and vendor-defined commands.
An action command refers to a command that performs a specific action in addition to
interacting with the local parameters of the MS, including AT+CPBR and AT+CMGS.
An action command may or may not contain parameters. Action commands are
categorized into execution (write) command and test command. A parameter
command refers to a command that interacts with the local parameters of the MS
only, certain of which may affect the execution of action commands. Parameter